HPV Multimatik CPU control unit for 2-bottle switchover system

  • HPV Multimatik CPU control unit for 2-bottle switchover system

    Code: 344480
  •  

    Maximum safety with maximum comfort.

    The Multimatik CPU automatically switches from an empty service cylinder to a full reserve cylinder. The control and switch panel inside the vehicle keeps you informed about the operating status of the gas system.

    Operate the refrigerator, heater or other consumers while driving and always be on the safe side. The patented "Crash Protection Unit" - CPU immediately interrupts the gas supply in an emergency and thus prevents the worst. It complies with all EU heater directives according to 2001/56/EC, including the special regulations for France.

    Whether in the event of emergency braking, an accident or an unusually large incline, the CPU interrupts the gas supply immediately. In addition, almost all common gas warning devices can be connected directly to the CPU electronics. In the event of a gas alarm, the gas supply is then also interrupted immediately for your greatest possible safety. During standstill as well as when driving, you enjoy the highest comfort with maximum safety with the CPU.

    Technical data:

    • Flow rate: 1.5 kg/h
    • Regulator inlet: external thread M 20 x 1.5
    Type of gas-related product Canister accessories
    Colour grey
    Connection 30 mbar
    Weight 1,93 kg